June 29, 2016
“'Tween:” How to Identify the ZF6HP Series Valve Body that Bridges the 1st & 2nd Generation Designs
Maura Stafford
VerifyOE valve & sleeve measurements before use.
There are some small diameter and length differences that can cause fit and pressure issues if mismatched into the wrong application. It is recommended to measurethe locations shown hereto verify that the correct OE or replacement part is fit into the appropriate application during rebuild.
Application | A | B | C | D | E | F | G |
---|---|---|---|---|---|---|---|
ZF6 Gen. 1, 6R60, 6R75, 6R80 ('09–'14) | .645" | .629" Dia. | .495“dia。 | .568" | .378“ | .629" Dia. | .550“DIA。 |
ZF6 Gen. 1 w/ 053 Separator Plate | .725" | .657“DIA。 | .511" Dia. | .649“ | .378“ | .657“DIA。 | .586" Dia. |
ZF6 Gen. 2 | .804" | .629" Dia. | .511" Dia. | .725" | .418“ | .629" Dia. | .562" Dia. |
6R80 ('15-Later), 6R100 | .645" | .629" Dia. | .511" Dia. | .568" | .378“ | .629" Dia. | .550“DIA。 |
Vehicles equipped with ZF6HP19, ZF6HP26 and ZF6HP32 transmissions often develop erratic or high line pressure due to excessive wear in the OE pressure regulator sleeve. This wear allows balance oil loss, preventing proper line pressure regulation. Without correct balance oil pressure, the pressure regulator valve will be out of its desired position, resulting in line pressure instability and possibly restricting cooler and lube flow. Installing Sonnax pressure regulator sleeve 95740-79 renews pressure regulator action for revived line pressure control in all ranges.
设备不兼容ZF6HP21/28/34 (Gen.2) units. To differentiate between Gen. 1 and Gen. 2 valve bodies, seeZF识别指南。
Sonnax阀门身体布局提供各个单位的详细概述,使其能够快速且易于确定您正在处理的特定阀体的内容。See all Sonnax valve body layouts.
June 29, 2016
Maura Stafford
2014年1月14日
June 22, 2016
September 30, 2005
Gregg Nader
10月8日,2020年
Maura Stafford
所指示的端口的真空测试未能保持推荐的最低型,或者在目视检测到磨损。